Description:
LCOS FX 10.13 RC1 is the first Release Candidate, that can also be installed via the the online updater instead of having to reinstall the Unified Firewall via the ISO file. It is also possible to perform an update from the Release Candidate to the Release firmware, when it is released.
This article describes the required steps to perform a firmware update to a Release Candidate on a Unified Firewall via the online updater.
Requirements:
- Configured and functional Internet connection
- Web browser to configure the Unified Firewall
The following web browsers are supported:- Google Chrome
- Chromium
- Mozilla Firefox
Procedure:
1) Open the webinterface of the Unified Firewall and got to the menu Firewall → Updates Settings.
2) Go to the tab Settings and for the existing update URL click the "Pencil" icon to edit the entry.
3) Enter the following URL and click on the check mark to implement the new URL.
https://firmware.fx-update.lancom-systems.com/rc/
Only one URL must be entered. As the Unified Firewall only checks the first URL, otherwise only release versions are displayed.
If you want to perform an update to a release firmware, edit the entry for the Update Server and enter the following URL:
https://firmware.fx-update.lancom-systems.com
4) Go back to the tab Updates and click on the button Refresh Updates List.
5) Select the Release Candidate and click Install.