Info |
---|
Connection monitoring is not implemented in WireGuard. Therefore a connection is always shown as active after the connection setup, even if the connection setup hasn't been completed. |
Hinweis |
---|
The WireGuard currently only works correctly on Unified Firewalls with one Internet connection. On a Unified Firewall with more than one Internet connection standard currently does not support multiple WAN connections. Therefore it is not possible to select a specific WAN connection for a WireGuard connection. Due to this reason, no data can be transmitted via the WireGuard connection on a Unified Firewall with more than one Internet connection, as the Unified Firewall sends the response packets via another Internet connection than incoming packets.This behavior will be fixed in a future LCOS FX version. |
Requirements:
- Two LANCOM R&S®Unified Firewalls with LCOS FX 10.12 or later
- A configured and functional Internet connection with local network on each Unified Firewall
- Web browser for configuring the Unified Firewall.
The following browsers are supported:- Google Chrome
- Chromium
- Mozilla Firefox
...